Now showing items 1-10 of 10

    • Hunn, B. D.; Grasso, M. M.; Vadlamani, V. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)
      This paper presents the results of an exploratory study of a fabric/desiccant window cavity dehumidifier system for possible use in commercial buildings. The objective was to evaluate fabrics commonly used in buildings, ...
    • Hunn, B. D.; Silver, S. C. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1988)
      An apartment building in Austin, Texas, and one in Boston, Massachusetts, were analyzed to determine the cost-effectiveness of energy efficiency measures. To determine expected energy and cost savings resulting from a set ...
    • Reddy, S. N.; Hunn, B. D.; Hood, D. B. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1994)
      This paper presents the development of a methodology to determine retrofit energy savings in buildings when few measured preretrofit data are available. Calibration of the DOE-2 building energy analysis computer program ...
    • Hou, D.; Jones, J. W.; Hunn, B. D.; Banks, J. A. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)
      A new approach is described for the development of Heating, Ventilating, and Air-conditioning (HVAC) System Performance Criteria for the Texas Building Energy Design Standard. This approach integrates a design of experimental ...
    • Hunn, B. D.; Jones, J. W.; Silver, S. C. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1988)
      In 1977, the State of Texas published a two-part Energy Conservation Manual to aid designers, builders, and contractors in the design of energy-efficient state buildings. Under the sponsorship of the Governor's Energy ...
    • Hunn, B. D.; Baughman, M. L.; Silver, S. C.; Rosenfeld, A. H.; Akbari, H. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1985)
      This paper presents preliminary results of a study of electrical energy conservation and peak demand reduction potential for the building sector in Texas. Starting from 1980 building stocks and energy use characteristics, ...
    • Hunn, B. D.; Banks, J. A.; Reddy, S. N. (Energy Systems Laboratory (http://esl.eslwin.tamu.edu), 1992-05)
      This paper presents the methodology and results of a detailed energy analysis of the Texas Capitol Restoration. The purpose of this analysis was two-fold: 1) to determine the projected energy cost savings of a series of ...
    • Pletzer, R. K.; Jones, J. W.; Hunn, B. D. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1987)
      Potential annual energy savings resulting from window shading devices on three prototypical Austin, Texas, single-family residences were computed in this study. Savings were calculated for interior (shades, blinds, draperies, ...
    • Carnes, D.; Hunn, B. D.; Jones, J. W. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1998)
      The Energy Utilization Index, energy consumption per square foot of floor area, is the most commonly used index of building energy consumption. However, a building or facility exists solely to support the activities of its ...
    • Doan, E. C.; Hunn, B. D.; Jones, J. W.; Gatton, T. M. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1996)
      Demonstration of compliance with the Texas Building Energy Conservation Design Standard involves completion of a summary checklist for each of its sections. This manual checking is tedious. Furthermore, no comprehensive ...